BEDES Dictionary

Version 2.6

You can explore the BEDES dictionary in several ways: use the search box to search for a particular term; filter the list of terms by category using the checkboxes below; click on each term for more details. You can also download all the terms and list options in CSV or XML format using the buttons below.

All Terms:
BEDES TERMS CSV [version]BEDES TERMS XML [version]
All List Options:
BEDES LIST OPTIONS CSV [version]BEDES LIST OPTIONS XML [version]
 
Filter By Category
Measures
Termsort descending Term Definition Lists Unit of Measure
Report Name

Name of the report.

None
Reporting Level

level or boundary of reporting metrics for this record.

View None
Residual Value

The estimated worth of an asset after the asset has fully depreciated

$
Resource Cost Savings $
Resource Cost Savings Intensity $/ft2
Resource Savings

Energy or water resource savings that can be realized from a measure or a project. This term can also further explained by using a relevant entry from the term Interval Frequency.

Unknown
Resource Savings Intensity

Resource savings per square foot.

Unknown
Retro Commissioning Exemption

Conditions under which the building is exempt from a mandated retro-commissioning.

None
Savings Attribution

Type of savings associated with a measure or project. Complete constrained list options include constrained lists from Energy Resource and Water Resource.

View None
Scope

Percentage of the premises affected by the measure that's either proposed, implemented or evaluated

percent
Technology Category

Categories of technology that can be used as qualifiers for Measures or other terms. Categories are inclusive of systems defined.

View None
Work Performed By

Entity who performed the work.

View None
HVAC
Termsort descending Term Definition Lists Unit of Measure
Absorption Heat Source

Source of heating energy for regeneration

View None
Absorption Stages

Number of stages in regeneration process

View None
Active Dehumidification

Availability of an active dehumidification system (in addition to the dehumidification that takes place during normal DX cooling operation).

View None
Air Distribution Type

Basic configuration of air-distribution equipment.

View None
Air Side Economizer

Presence of air-side economizer to provide free cooling.

View None
Air Side Economizer Type

Type of air economizer system associated with a cooling system.

View None
Belt Type

Type of belt drive in fan unit

View None
Boiler Blowdown Rate

A blowdown of the boiler is a routine operation necessary due to the increased concentration of Total Dissolved Solids - TDS - in the boiler during the steam production. The blowdown rate of a boiler depends on: steam consumption (steam used in the process and not returned as condensate to the boiler), concentration of impurities in the feed water, maximum allowable TDS in the boiler.

kg/hr
Boiler Insulation R Value

Insulation R-Value of hot water storage tank.

hr-ft2-F/Btu
Boiler Insulation Thickness

Insulation thickness of hot water storage tank. [inches]

in
Boiler Percent Condensate Return

The percentage of condensed steam that is returned to the boiler.

percent
Burner Turndown Ratio

If applicable, the turndown ratio for the burner (full input/minimum input).

None
Burner Type

Type of burner on boiler or furnace, if applicable.

View None