BEDES Dictionary
Version 2.6
You can explore the BEDES dictionary in several ways: use the search box to search for a particular term; filter the list of terms by category using the checkboxes below; click on each term for more details. You can also download all the terms and list options in CSV or XML format using the buttons below.
Term | Term Definition | Lists | Unit of Measure | |
---|---|---|---|---|
Plumbing Penetration Sealing |
Type of plumbing penetration sealing |
View | None | |
Radiant Barrier |
Type of radiant barrier in the construction |
View | None | |
Radiant Barrier Location |
Installed location of radiant barrier |
View | None | |
Roof Shape |
Architectural description of the exterior shape of the roof. If the roof has more than one shape, this is the primary roof shape. Illustrations to be added when the website is developed. |
View | None | |
Shading System |
A system that can be added to a fenestration system which blocks or redirects some amount of the solar radiation coming through the fenestration system. A shading system can be located on the inside or outside of a fenestration system, and it can also be added between the glass (or plastic) layers of a glazing system. The location can be specified using the Location term. |
View | None | |
Shell Area |
The total surface area of the exterior envelope of a building |
ft2 | ||
Sill Height |
Distance from the floor to the lower horizontal surface at the window opening. |
ft | ||
Solar Heat Gain Coefficient |
The ratio of the solar heat gain entering the space through the fenestration product to the incident solar radiation. Solar heat gain includes directly transmitted solar heat and that portion of the absorbed solar radiation which is then reradiated, conducted, or convected into the space. Legal values: 0-1. |
None | ||
Solar Reflectance Index |
A measure of a roof's ability to reject solar heat, as shown by a small temperature rise. It is defined so that a standard black (reflectance 0.05, emittance 0.90) is 0 and a standard white (reflectance 0.80, emittance 0.90) is 100. SRI |
None | ||
Vertical Surroundings |
Attachments to the outermost vertical surfaces of the premises. |
View | None | |
Visible Transmittance |
The fraction of radiation in the visible solar spectrum (0.4 to 0.7 micrometers) that passes through a material. Legal values: 0-1. |
None | ||
Weatherstrip Description |
Material used in weatherstipping application. This can apply to doors, windows, as well as system components such as refrigeration doors. |
View | None | |
Weatherstrip Status |
Whether a premises or feature, such as a door or window, is weatherstripped. |
View | None | |
Window To Wall Ratio |
Ratio of total window area to total wall area, where the total wall area is calculated using the floor to floor height, rather than the floor to ceiling height. |
None |
Term | Term Definition | Lists | Unit of Measure | |
---|---|---|---|---|
Age |
Age of premises or equipment in years. |
years | ||
Area |
The space inside the boundary of a 2 dimensional shape. This can be used with many other terms, including Location, Conditioning Status, Opaque Surface, to characterize the area of particular components. |
ft2 | ||
Aspect Ratio |
The ratio of width to length, of a premises |
None | ||
Azimuth |
Degrees clockwise from North. For a premises, it is the azimuth of the front facing element. It can also be applied to envelope components, such as walls, windows (fenestration), as well as on-site generation technologies, such as photovoltaic panels. Legal Values: 0 - 360 |
deg | ||
Boolean |
Generic term to add boolean constrained list options to any term |
View | None | |
Building Energy Code Or Standard |
The name of an energy efficiency code or standard that is applied to building construction requirements. |
View | None | |
Building Energy Code Or Standard Version |
The version number, such as "90.1" for ASHRAE Standard. |
None | ||
Building Energy Code Year |
Year for the Energy Code or Standard used with the Energy Code term. As the energy codes and standards are updated, dates are assigned for version control. There can be significant changes between different year versions, so it is important to capture the year of the standard as it applies to the building in question. |
YYYY | ||
Capacity |
The capacity value of the associated equipment or system |
Unknown | ||
Capacity Qualifier |
The capacity refers to the energy or physical load amount that equipment can handle. |
View | None | |
Cardinal Orientation |
Orientation of a surface or premises in terms of the attributes of North, South, East and West. Can be applied to the orientation of the front of the building, of a specific surface (wall, roof), window or skylight, or on-site generation technology, such as photovoltaic panels. A diagram for the constrained list choices will be provided when the web site is developed. |
View | None |