The equipment state of connection to a power source for use, and providing one or more primary functions.
Data Type:
Constrained List
Category:
Unit of Measure:
None
Sector:
Commercial, Residential, Multifamily
The equipment state of connection to a power source for use, and providing one or more primary functions.
List Options | Option Definition | Unit of Measure | |
---|---|---|---|
Active | The operational state in which the machine is carrying out primary work. | None | |
Dwell | For stationary rack machines, the dishwasher is in dwell mode when it is actively running a cycle but is not in wash or rinse modes. | None | |
Energy saver | Energy saver mode is a setting that consumes less energy than it does in idle mode. | None | |
High activity standby | Produces no functional output, but can be switched into another mode with the remote control unit or an internal signal, and with an external signal, and is exchanging/receiving data with/from an external source. | None | |
High data rate | Traffic is passed across ports of equipment at a selected reference rate, considered high data rate such as for network. | None | |
Idle | The machine server is operational, but not performing any useful work. | None | |
Low activity standby | Produces no functional output, but can be switched into another mode with the remote control unit or an internal signal, and with an external signal, and is not exchanging/receiving data with/from an external source. | None | |
Low data rate | Traffic is passed across ports of equipment at relatively slow data rate. For instance, network data rate of 1.0 kb/s (0.5 kb/s in each direction) as defined in the Energy Star test procedure. | None | |
None | None | None | |
Not applicable | Not applicable | None | |
Off | Not connected to a power source, produces no function, and cannot be switched into any other mode with a remote control unit, an internal signal, or an external signal. | None | |
On | Connected to a power source, activated, receiving a main charge or ready to use, and is providing one or more of its primary functions. | None | |
On demand | Power is supplied as it is required by demand | None | |
Other | Other | None | |
Passive standby | Produces no functional output, but can be switched into another mode with the remote control unit or an internal signal. Has no saved hardware state. For instance, the Game Console has no active network link although may be capable of charging devices in this mode. The lowest power consumption mode which cannot be switched off (influenced) by the user and that may persist for an indefinite time when an appliance is connected to the main electricity supply. Standby mode: a) no battery is present in the charger, or, where the battery is integral to a product, the product is not attached to the charger, b) the charger is connected to mains, and c) any manual power switches are switched on. | None | |
Ready state | The power state in which a product is not producing output, has reached operating conditions, has not yet entered into any lower-power modes, and can enter Active State with minimal delay. | None | |
Rinse | Rinse mode is when the machine is at the end of the actively running cycle and is spraying rinse water. | None | |
Schedule | Power is supplied according to an associated schedule | None | |
Sleep | A reduced power state that a product enters either automatically after a period of inactivity. For products evaluated under the TEC test method, Sleep Mode permits operation of all product features (including maintenance of network connectivity), albeit with a possible delay to transition into Active State. For products evaluated under the OM test method, Sleep Mode permits operation of a single active network interface, as well as a fax connection if applicable, albeit with a possible delay to transition into Active State. | None | |
Standby | The lowest power consumption state which cannot be switched off by the user and that may persist for an indefinite time when the product is connected to the main electricity supply. | None | |
Unknown | Unknown | None | |
Updating | Actively engaged in system maintenance or download updated functionality after waking or in response to user input. | None | |
Wash | Wash mode is when the machine is actively running a cycle and is spraying wash water. | None |
CSV or XML files containing information such as definition, unique ID, and URL for each BEDES Term or List Option can be downloaded by clicking the appropriate orange button. The downloaded file can then be processed offline. Note that the XML documents are simply a "flat file" of terms, not a structured schema.