Type of cooling or heating system
Data Type:
Constrained List
Category:
Unit of Measure:
None
Type of cooling or heating system
List Options |
Option Definition![]() |
Unit of Measure | |
---|---|---|---|
Absorption chiller | None | ||
District chilled water | None | ||
Fireplace | None | ||
Heating stove | None | ||
No cooling | None | ||
No heating | None | ||
None | None | ||
Not applicable | None | ||
Other | None | ||
Unknown | None | ||
Vapor compression chiller | None | ||
District heating | A centrally located plant that is used for heating. Use "Cooling Heating Medium" to further categorize as hot water or steam, if desired. | None | |
District steam to hot water HX | A centrally located plant that is used to generate steam that is then moved through a heat exchanger to create hot water for heating. | None | |
Evaporative cooler | A cooler that cools indoor air by moisture evaporation, thereby lowering its dry-bulb temperature and raising its wet-bulb temperature, all at a constant energy (adiabatic) level | None | |
Packaged terminal air conditioner | A packaged terminal air conditioner, or PTAC, is a self-contained air conditioning system commonly found in hotels, motels, senior housing facilities, hospitals, condominiums, apartment buildings, add-on rooms and sunrooms. | None | |
Packaged terminal heat pump | A Packaged terminal heat pump, or PTHP, is a factory-packaged refrigerant-based heat pump with no air distribution system other than a built-in fan. | None | |
Packaged unitary direct expansion RTU | A unit that includes all the components- evaporative coil, compressor, expansion valve, condenser coil, and fans that's installed outside and the supply air is ducted inside. A separate heating source- electric or gas pack- is added if needed | None | |
Solar thermal | Air or water heated using solar collectors | None | |
Built in heater | Built-in heater is a category intended to represent wall or floor mounted units that generate and deliver heat to a local zone such as wall-mounted electric heating panels. | None | |
Single package vertical air conditioner | Compact through-the-wall packaged system capable of providing total heating and cooling functions for a single zone or multiple rooms, designed with sufficient air-handling capacity for ducted installations. | None | |
Single packaged vertical heat pump | Compact through-the-wall packaged system capable of providing total heating and cooling functions for a single zone or multiple rooms, designed with sufficient air-handling capacity for ducted installations. | None | |
Packaged unitary heat pump | Factory-packaged refrigerant-based heat pump with an air distribution system and a reversing valve to alter the flow of refrigerant based on the need. | None | |
Chiller | Generic chiller | None | |
Heat pump | Generic heat pump | None | |
Individual space heater | Individual space heater is a category intended to represent a free-standing or self-contained unit that generates and delivers heat within a local zone. These heaters are characterized by a lack of pipes or ductwork for distributing hot water, steam, or warm air through a building. These heaters are portable and would include electric radiant or quartz heaters, heating panels, gas- or kerosene-fired or electric unit heaters, and infrared radiant heaters. | None | |
Furnace warm air | Packaged assembly of components that includes a heating source, a fan and an air filter, that relies on convection for heating delivery | None | |
Furnace | Packaged assembly of components that includes a heating source, a fan and an air filter, that relies on convection for heating delivery. Use "Cooling Heating Medium" to specify air if desired. | None | |
Split DX air conditioner | Split direct expansion | None | |
Variable refrigerant flow | System using refrigerant as the cooling and heating medium, conditioned by a single outdoor condensing unit, and circulated within the building to multiple fan-coil units. The system supports variable motor speed and thus variable refrigerant flow rather than simply on/off operation. | None | |
Boiler | Use "Cooling Heating Medium" to further categorize the boiler as hot water or steam, if desired. | None |
CSV or XML files containing information such as definition, unique ID, and URL for each BEDES Term or List Option can be downloaded by clicking the appropriate orange button. The downloaded file can then be processed offline. Note that the XML documents are simply a "flat file" of terms, not a structured schema.